| Short Biographical Sketch |
Prof. Dr. Marc KachelrießDr. Marc Kachelrieß was born in 1969 in Nürnberg, Germany. In 1989 he began to study physics with a focus on theoretical particle physics. His diploma thesis was entitled “Meson exchange currents in light nuclei”. He received his diploma at the Friedrich-Alexander-University of Erlangen-Nürnberg in 1995.
Then, Marc Kachelrieß started his dissertation at the Institute of Medical Physics (IMP) under the guidance of Prof. Willi A. Kalender. He developed reconstruction algorithms to reduce metal artifacts in x-ray computed tomography (CT). In parallel, Marc Kachelrieß introduced a new method that allows to generate motion-free images of the human heart using standard CT data. Thereby the clinical feasibility of retrospective electrocardiogram-correlated image reconstruction from CT data was proven. This method is now in world-wide use in clinical CT scanners. Marc Kachelrieß received his Ph.D. at the IMP in 1998.
Since then, he focuses on cardiac imaging and extended the approaches to future scanner generations. Other fields of his research work are image reconstruction of cone-beam CT data, iterative image reconstruction, image reconstruction algorithms in general. He is involved in developing algorithms for automatic exposure control (AEC) for CT, methods to reduce CT artifacts and patient dose reduction techniques. His work also includes the design and development of micro CT scanner hard- and software, micro CT pre- and postprocessing software and image quality optimization techniques.
In 2002 Marc Kachelrieß completed all post doctoral lecturing qualifications (habilitation) for Medical Physics and in 2005 he was appointed W2-Professor of Medical Imaging at the Friedrich-Alexander-University Erlangen-Nürnberg, Germany. On the basis of his university teaching position he lectures in medical imaging technology, physics and algorithms.
| Type of publication / Art der Arbeit |
Number / Anzahl
|
| Original scientific publication / Wissenschaftliche Originalarbeit |
34 (16) |
| Review article,
Invited publication / Übersichtsartikel, Beitrag nach Aufforderung |
10 (4) |
| Textbook contribution / Buchkapitel |
9 (7) |
| Proceedings volume / Buchbeitrag |
49 (36) |
| Published abstract / Veröffentlichte Vortragskurzfassung |
147 (64) |
| Patents / Patentschriften |
5 (2) |
| Invited Lectures / Eingeladene Vorträge |
8 (7) |
| others / andere | 3 (3) 266 (139) |
| Selected Publications |
C. Maass, M. Baer, and M. Kachelriess. Image-based dual energy CT using optimized precorrection functions: A practical new approach of material decomposition in image domain. Med. Phys. 36(8): 3818-3829 pdf
F. Bergner, T. Berkus, M. Oelhafen, P. Kunz, T. Pan, M. Kachelrieß. Autoadaptive phase-correlated (AAPC) reconstruction for 4D CBCT. Med. Phys. 36(12): 5695-5706 pdf
P. Stenner, B. Schmidt, H. Bruder, T. Allmendinger, U. Haberland, T. Flohr, M. Kachelrieß. Partial scan artifact reduction „PSAR… for the assessment of cardiac perfusion in dynamic phase-correlated CT. Med. Phys. 36(12): 5863-5694 pdf
R. Grimmer, M. Oelhafen, U. Elstrøm, M. Kachelrieß. Cone-beam CT image reconstruction with extended z-range. Med. Phys.2009; 36(7):3363-3370 pdf
S. Steckmann, M. Knaup, M. Kachelrieß. High performance cone-beam spiral backprojection with voxel-specific weighting. Phys Med Biol . 2009 Jun 21;54(12):3691-3708 pdf
- Maaß, M Knaup, R Lapp, M Karolczak, WA Kalender, M Kachelrieß. A new weighting function to achieve high temporal resolution in circular cone-beam CT with shifted detectors. Med. Phys. 2008; 35(12): 5898-5909 pdf
P. Stenner, M. Kachelrieß. Dual energy exposure control (DEEC) for computed tomography: Algorithm and simulation study. Med. Phys. 2008; 35(11): 5054-5060 pdf
S. Steckmann, M. Knaup, M. Kachelrieß. Hyperfast general-purpose cone-beam spiral backprojection with optional voxel-specific weighting. High-Performance Medical Image Computing & Computer Aided Intervention HP-MICCAI Conference Record, September 2008. (This paper was awarded the best paper of the workshop “High-Performance Medical Image Computing & Computer Aided Intervention” at the 2008 MICCAI meeting) pdf
P. Stenner, T. Berkus, M. Kachelriess. Empirical dual energy calibration (EDEC) for cone-beam computed tomography. Med. Phys. 2007; 34(9): 3630-3641. (This work received the Werner von Siemens Excellence Award 2008) pdf
Kachelrieß M, Knaup M, Bockenbach O. Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware. Med. Phys. 2007; 34(4): 1474-1486 pdf
M. Kachelrieß, M. Knaup, O. Bockenbach. Hyperfast Parallel–Beam Backprojection. IEEE Medical Imaging Conference 2006 pdf
M. Kachelrieß, T. Berkus, P. Stenner, W. A. Kalender. Empirical dual energy calibration (EDEC) for cone-beam computed tomography. IEEE Medical Imaging Conference 2006 pdf
M. Kachelrieß, M. Knaup, O. Bockenbach. Hyperfast Perspective Cone–Beam Backprojection. IEEE Medical Imaging Conference 2006 pdf
M. Kachelrieß, M. Knaup, and W.A. Kalender. Multithreaded cardiac CT. Med. Phys. 33(7): 2435-2447, July 2006 pdf
- M. Kachelrieß, M. Knaup, C. Penßel, and W.A. Kalender. Flying Focal Spot (FFS) in Cone-Beam CT.
IEEE Transactions on Nuclear Science 53(3), June 2006 pdf
M. Kachelrieß, K. Sourbelle, and W. A. Kalender. Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography. Med. Phys. 33(5): 1269-1274, May 2006 pdf
M. Kachelrieß, W. A. Kalender. Optimizing detector size in X-ray imaging. IEEE Medical Imaging Conference 2005 pdf
M. Kachelrieß, W. A. Kalender. Improving PET/CT attenuation correction with iterative CT beam hardening correction. IEEE Medical Imaging Conference 2005 pdf
K. Sourbelle, M. Kachelrieß, and W. A. Kalender. Empirical water precorrection for cone-beam computed tomography. IEEE Medical Imaging Conference 2005 pdf
Kachelrieß M, Kalender WA . Optimizing Detector Size in X-Ray CT Imaging. International Conference of Medical Physics 2005. Biomedizinische Technik 2005, Vol.50, Suppl.vol.1, Part 2: 1160-1161 pdf
M. Kachelrieß, M. Knaup, C. Penßel, and W.A. Kalender. Flying focal spot (FFS) in cone-beam CT.
Records of the 2004 IEEE Medical Imaging Conference, 3759-3763, 2005 pdfM. Kachelrieß, M. Knaup, and W.A. Kalender. Phase-correlated imaging from multi-threaded spiral cone-beam CT scans of the heart. Proc. of the 2005 Int. Meeting on Fully 3D Image Reconstruction:159-162, July 2005 pdf
M. Kachelrieß and W.A. Kalender. Presampling, algorithm factors, and noise: Considerations for CT in particular and for medical in general. Med. Phys. 32(5): 1321-1334, May 2005 pdf
M. Kachelrieß, M. Knaup, and W.A. Kalender. Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage. Med. Phys. 31(6): 1623-1641, June 2004 pdf
M. Kachelrieß. Phase-correlated dynamic CT. 2004 pdf
M. Kachelrieß, T. Berkus, and W.A. Kalender. Quality of statistical reconstruction in medical CT. Records of the 2003 IEEE Medical Imaging Conference, M10-325, 5 pages, April 2004. pdf
M. Kachelrieß, M. Knaup, and W.A. Kalender. 4D reconstruction for wide cone-angle medical CT. Records of the 2003 IEEE Medical Imaging Conference, M15-5, 5 pages, April 2004. pdf
M. Kachelrieß and W.A. Kalender. Extended Parallel Backprojection (EPBP) for Arbitrary Cone Angle and Arbitrary Pitch 3D and Phase Correlated 4D CT Reconstruction. Proc. of the 7th Int. Meeting on Fully 3D Image Reconstruction, June 2003. pdf
M. Kachelrieß, D.-A. Sennst, W. Maxlmoser, and W.A. Kalender. Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med. Phys. 29(7): 1489-1503, July 2002. pdf
M. Kachelrieß. Image quality and dose in CT: Current practice, new developments and optimization. Refresher Course, Wien 4.3.2002 European Radiology, 12 Suppl. 1: 92, February 2002 (Invited Lecture) html
M. Kachelrieß. Single-Slice, Multi-Slice and Cone-Beam Spiral CT: Technical Aspects and Clinical Applications. JRF Highlighted Lecture, Wien 2.3.2002 European Radiology, 12 Suppl. 1: 44, February 2002. (Invited Lecture) html
M. Kachelrieß. Neue Methoden der Herzbildgebung mit Spiral CT. Öffentliche Antrittsvorlesung am 18.02.2002 in Erlangen. html
M. Kachelrieß, T. Fuchs, S. Schaller, and W.A. Kalender. Advanced single-slice rebinning for tilted spiral cone-beam CT. Med. Phys., 28(6): 1033-1041, June 2001. pdf
M. Kachelrieß, O. Watzke, and W.A. Kalender. Generalized multi-dimensional adaptive filtering (MAF) for conventional and spiral single-slice, multi-slice and cone-beam CT. Med. Phys., 28(4): 475-490, April 2001. (This paper received the Walter Friedrich Award of the Deutsche Röntgengesellschaft in 2001). pdf
M. Kachelrieß, T. Fuchs, R. Lapp, D.-A. Sennst, S. Schaller, and W.A. Kalender. Image to volume weighting generalized ASSR for arbitrary pitch 3D and phase-correlated 4D spiral cone-beam CT reconstruction. Proc. of the 2001 Int. Meeting on Fully 3D Image Reconstruction, 179-182, November 2001. pdf
M. Kachelrieß, S. Ulzheimer, and W.A. Kalender. ECG-correlated imaging of the heart with subsecond multislice CT. IEEE Transactions on Medical Imaging, 19(9): 888-901, September 2000. pdf
M. Kachelrieß, S. Ulzheimer, and W.A. Kalender. ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med. Phys., 27(8): 1881-1902, August 2000. pdf
M. Kachelrieß, S. Schaller, and W.A. Kalender. Advanced single-slice rebinning in cone-beam spiral CT: Theoretical considerations and medical applications. SPIE Medical Imaging Conference Proc., 3979: 494-505, February 2000. pdf
M. Kachelrieß, S. Schaller, and W.A. Kalender. Advanced single-slice rebinning in cone-beam spiral CT. Med. Phys., 27(4): 754-772, April 2000. (This paper received the Sylvia Sorkin Greenfield Award for the best scientific paper in Medical Physics during 2000). pdf
M. Kachelrieß and W.A. Kalender. Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med. Phys., 25(12): 2417-2431, December 1998. (This paper received the Sylvia Sorkin Greenfield Award for the best scientific paper in Medical Physics during 1998). pdf
M. Kachelrieß and W.A. Kalender. Imaging of the heart by ECG-oriented reconstruction from subsecond spiral multi-row detector CT scans. Radiology, 209(P): 323, November 1998
M. Kachelrieß. Reduction of Metal Artifacts in X-Ray Computed Tomography. PhD Thesis, Friedrich-Alexander-Universität Erlangen-Nürnberg, 1998. pdf
M. Kachelrieß M. and W.A. Kalender
ECG-based phase-oriented reconstruction from subsecond spiral CT scans of the heart. Radiology 205(P): 215, 1997